Azteca
AC Series-Features
|

|
|
MICROPROCESSOR CONTROLLED STEAM STERILIZER
|
|
The
Azteca AC Sterilizer uses steam under pressure as the sterilizing agent
for wrapped or unwrapped goods such as fabrics, surgical instruments,
utensils, and other heat and moisture stable materials at temperatures
ranging from 105°C to 138°C. The Sterilizer has an operating range of
up to 2.5 Bar / 138°C.
The Azteca AC sterilizer is a pre-vacuum/gravity sterilizer designed to
cover a large field of applications for hospitals and medical centers.
Within the health care services, sterilization of medical supplies is
an essential issue in the battle against the advance of many infectious
diseases. In order to improve the quality of sterile supply,
international standards, which specify the requirements for the
equipment, and procedures in the sterilization departments in health
care facilities, have been developed.
|
|
DESIGN AND CONSTRUCTION
|
|
The
Azteca AC Sterilizer meets the highest standards requirements for
quality, safety and operation. Stainless Steel Pressure Vessels 316 Ti
conforms to the Pressure Equipment Directive (PED). The inner shell,
door(s) and jacket are designed for a maximum working pressure of 2.5
bar and full vacuum.
|
|
CHAMBER
|
|
The
Vessel is double-wall constructed with a round chamber, made of
corrosion-resistant electro-polished stainless steel 1.4571 (V4A) AISI
316 Ti, and is thus easy to clean. The sterilizer’s framework and
housing are also made of stainless steel. The highly efficient,
high-quality Hanno-Tech insulation material releases no particles;
thus, the Azteca AC Series can be used under clean room conditions.
|
|
DOOR (S)
|
|
The
sterilizer is supplied with either 1 or 2 hinged door(s) with an
automatic door locking device. Special safety features prevent the
operator from opening the door when the chamber is pressurized or when
the temperature is high.
|
|
GASKET
|
|
The
sealing of the chamber is made by utilizing a heat-resistant silicone
rubber gasket.
|
|
MOUNTING FRAME
|
|
A
galvanized steel frame with rustproof painted finish and height
adjustable leveling bolts supports the sterilizer’s chamber and piping.
|
|
CONTROL SYSTEM
|
|
A
microprocessor based control system, state of the art “Freescale”
technology, automatically controls all programs including the
sterilization cycle. The system includes a graphic display,
communication, self and remote diagnosis and PC connection for external
documentation and printing. It ensures a reliable, safe and
user-friendly operation. The displayed information is available for
users in a variety of languages.
During the sterilization cycle the control system measures, controls
and shows in digital display: the time, chamber temperature, chamber
pressure and sterilization status.
While the power is off, the non-volatile memory keeps the status of the
sterilizer, and the real-time clock, driven by its own back-up battery,
keeps running the date and time.
|
|
ENERGY SAVING MODE
|
|
The
Azteca AC Sterilizer is equipped with an Energy Saving Mode which is
activated when the unit is not used after a certain period of time.
This Mode saves energy and ensures safety of operation and is thus
environmental friendly.
|
|
|
ALARMS
|
|
Depending
on the state of the input and of the installed accessories, the
controller is capable of displaying and/or printing several alarms
including:
-Door Unlock
-Temperature/ Pressure Error
-Low/High Temperature
-Low/High Pressure
-Low Vacuum and more.
|
|
STERILIZATION AND TEST CYCLES
|
|
Up
to 20 sterilization and test cycles are available: flash cycle,
unwrapped instruments, wrapped instruments and packages, Prion cycle,
textile cycle and slow exhaust cycle.
The two available test programs are the Vacuum Test which checks the
integrity of the chamber and piping system and the Bowie & Dick
test which checks the efficiency of the sterilization process.
|
|
CYCLE DOCUMENTATION
|
|
For
a clear and concise documentation of processes, the control unit is
provided with a 24 character per line printer, connected to the
processing sterilizer.
This releases a hard copy printing of the relevant information
regarding operation during the cycle, such as temperature, pressure,
vacuum, sterilization and drying time, number of cycles, etc. In case
of an uncompleted cycle, the print-out indicates the cycle failure and
the cause of the failure. RS485/ RS232 PC communication port is
available for full documentation and optional advanced Windows based
software is available for monitoring, logging and control.
A circular or strip temperature and pressure chart recorder can be
supplied upon request.
|
|
STEAM GENERATOR
|
|
The
steam generation takes place in a vessel which is completely separated
from the sterilization chamber (i.e. no heating elements in the chamber
itself).
The steam generator is built-in into the sterilizer’s housing. As the
generator is separated from the chamber, it needs not be cooled during
the cool-down phase.
|
|
AIR COMPRESSOR
|
|
An
electrically operated air compressor is provided in order to prevent a
lack of available compressed air. The air is used to operate the
sterilizer’s ball valves and/or power door.
|
|
COMMUNICATION SYSTEM
|
|
PC Software
PC Software is available in order to collect and document the
sterilization programs. The connection is done through RS232, USB or
RS485.
Data Collection
Sterilization cycles’ data can be collected online on a SD card through
a SD card slot, and can be downloaded into a computer equipped with
proprietary PC Software. 1 Gigabyte SD card can collect up to 20 years
logging data which includes: the selected cycle, start time, cycle
stages, temperature/pressure, end time, cycle graph, cycle status
(pass/ fail), etc. All collected data can be printed via PC.
SD card/ Card reader
1 SD Card and 1 Card reader are included.
|
|
|